UPS Single Phase
UPS 3 Phase
Remote Eye II
UPS Quote Form

Click here to shop online
   
We Carry Outdoor Heated MatsHeated Mats are for use outdoors and come in 4 sizes and will keep your doorstep or sidewalk clear and dry of snow and ice.

Fire Shield Surge Strips are the safest surge protection - perfect for dorm rooms and off-campus housing.

 

TOSHIBA UPS

-----> Shop online for Toshiba Uninterruptible Power Systems (UPS) <-----

Toshiba

Contents:

bulletProduct Summary
bullet10 Compelling Reasons
bulletSingle Phase UPS
bullet3 Phase UPS
bulletQuote Form

Product Summary

Toshiba's full line of Uninterruptible Power Systems provide the best way to
preserve equipment and data during a power disturbance. Every Toshiba UPS is
designed, built and tested at our Houston manufacturing plant to ensure the highest
quality and reliability.

Regardless of the power disturbance, the Toshiba UPS can weather any storm. We
are truly Your System Lifesaver!

Back to Top

10 Compelling Reasons for using TOSHIBA UPS

Wide Input Voltage and Frequency windows

Slight voltage and frequency fluctuations force most UPS systems to operate off of battery power. Toshiba UPS systems are =10 to -30% voltage and 45-65 Hz. Frequent deep cycle battery discharges shorten the life of batteries and jeopardize the functional integrity of the UPS by leaving the batteries in a partially charged state. Toshiba's wide input voltage Window ensures that the output power remains continuos and regulated, regardless of input fluctuations, operating on battery power only during extreme brownouts and blackouts. Additionally, Toshiba UPS are designed to regulate frequency from its internal oscillator, without operating off the batteries during input frequency shifts. Benefit: Longer Battery life and longer battery time.

Input Power Factor Correction

The Toshiba UPS acts as a harmonic filter by incorporating Input Power Factor Correction. Toshiba uses a high speed transistor (IGBT) to correct the UPS input power factor to near unity (.98 to .99). Reducing reflected harmonics to below 5% THD - the best in the industry. Benefit: Less install cost for wiring and breakers and less negative affect on sensitive electronics on the same circuit.

Intelligent Charger

Toshiba's intelligent charger constantly monitors the batteries' rising voltage and decreases the charge current proportionally to the optimum characteristics of the battery. This delicate charging prolongs battery life to a 5-8 year expectancy 93 years guaranteed, full replacement) Benefit: Longer Battery Life, better warranty.

Crest Factor

Due to nonlinear current demands of today's computers high Crest factors can result and create square waves. Toshiba UPS are designed for these high crest factor non-linear loads resulting in a clan sinewave. Benefit: Toshiba UPS an be fully loaded and not "derated".

Overload capabilities

Toshiba uses high-powered IGBT transistors to give better overload capacity with having to parallel many small transistors which reduces inverter reliability. UPS systems without high overload capability continually transfer to bypass during the slightest overload. This leaves your application vulnerable to brownout and blackouts while in bypass mode. Benefit: Increased efficiency and reliability.

Clean Sinewave

The Toshiba UPS utilizes IGBT technology at 16 to 25 kHz to produce the cleanest sinewave output. A clean sinewave is a good measure of the quality and reliability of the UPS. Benefit: Protects sensitive electronics better.

Automatic Bypass

During extreme overloads, the Toshiba UPS will automatically "bypass" from inverter power and then switch back to full UPS operation when the overload condition is corrected. Without automatic bypass the load would be lost and possibly damaged. Benefit: Added reliability and redundancy.

Total Isolation

Electrical noise may cause parity errors, system lockups and irreparable damage to sensitive electronic equipment. This noise usually travels n the neutral to ground circuit path. In most environments, an isolation transformer is the most effective tool to eliminate this noise. Toshiba eliminates this noise by providing a low impedance isolation transformer on the output of every "Plus" Series UPS. Therefore the Toshiba UPS becomes a "separately derived power source," as defined by the NEC because the neutral is bonded to the ground on the transformer output. Benefit: Ultimate power conditioning.

Communication Features

The Toshiba UPS provides comprehensive monitoring of the UPS' output voltage, output load, battery time remaining, etc. Diagnostic information is provided through the RS-232C Communication Port making it easy for a service technician to diagnose any problem. Th feature makes the UPS "smart" SNMP compatible. Additionally, when this feature is combined with Toshiba's SNMP adapter, the user is able to monitor multiple Toshiba UPS sites from one central location. Benefit: Reliability and peace of mind.

3 Year Onsite Warranty

24 hour on site warranty, including parts, travel, labor, and batteries. Benefit: Peace of mind

 Back to Top

Single Phase UPS

There's no one better to entrust your power protection needs than Toshiba. We offer the most reliable and performance driven on-line UPS products in the world. Our commitment to excellence and quality in the design and manufacture of our equipment is unsurpassed. As a result, you are assured to receive the most technically advanced UPS available worldwide. Toshiba single phase units are built in the U.S. with U.S. parts, to ISO 9001 certification standards. Toshiba single Phase UPS systems are rated from .6 to 18 kva.

Go To Single Phase UPS page

Back to Top

3 Phase UPS

Toshiba's 4100 Series 3-Phase UPS provides the ultimate in premium power protection. All of Toshiba's 3-phase units come with several Exclusive Features that really set us apart from the competition. The 4100 system can be used for 15 to 100 kva loads and higher with parallel 4100's used together.

Go to Toshiba 3 Phase UPS page

Back to Top

Back to Top

 

Send mail to webmaster@anderson-bolds.com with questions or comments about this web site.
OH Electro-Mechanical distributes a broad line of motors, drives, and power transmission products.
The RSI Company manufactures and services Typhoon and Nesbitt products.
Copyright © 1996-2008 Anderson-Bolds, Inc.  |  (216) 360-9800 or (866) 360-9810  |  info@anderson-bolds.com